Coil 3-in-1 feeder is mainly used in the metal stamping industry for uncoiling, conveying, leveling and shearing of metal coils, which is an innovative feeding mechanism for KINGREAL’s stamping production. Hydraulic components are important parts of the coil 3-in-1 feeder, in the daily maintenance should pay attention to, so what measures can be implemented to protect the hydraulic components of the coil 3-in-1 feeder?


Knowledge about the inspection and maintenance of the hydraulic components of the
coil feeder.



As the use of manufacturers, we should check the condition of the hydraulic components every day, timely detection of problems, and maintenance. Before starting the machine, pay attention to the amount of oil, not higher or lower than the range allowed by the equipment. Also observe the oil thermometer, the oil temperature cannot be too low, the oil temperature is too low will seriously affect the operation of the machinery, resulting in the inability to run, this time we can enhance the oil temperature through the machine‘s own electric heating system, the follow-up observation of the oil gauge pointer is normal. 

In short, in the process of using the stamping three-in-one feeder, we must carefully and conscientiously observe the changes in the oil temperature table, pay special attention to keep the oil temperature control equipment and pressure control valve under working condition, and responsive, through the pressure indicator to observe whether the oil filter is blocked, but also pay attention to whether the oil pressure equipment has the phenomenon of oil leakage, oil leakage is generally due to the oil temperature is too high.



In addition to the above daily inspection of the three-in-one feeder, we can also carry out the first off, the regular inspection.


1. Check the thermometer, if the oil temperature is too low, you need to use the electric heater to heat or do warm machine operation.


2. Check the oil level according to the oil level meter of the oil policy to ensure that the oil level is within the specified range.


3. Check how the maintenance of the mailbox, whether there is oil leakage or rust, and timely maintenance, test whether the oil pump is loose, and whether there is any problem with the piping system.


4. Check the abnormality of pressure gauge pointer.


5. For all the measuring equipment, such as oil thermometer, oil gauge, cooling equipment, oil filter, pressure gauge, etc.


6. To detect whether there is air inside the equipment, it is enough to remove the exhaust gas in time.  


The above is the commonly used measures to maintain the coil 3-in-1 feeder oil pressure components, I hope it will help you. Maintain the daily condition of the hydraulic components is more conducive to the long-term use of the coil 3-in-1 feeder.